Picture of Telemecanique MODULAR RELAY 16/10 I/O RELAY OUTPUT

Telemecanique MODULAR RELAY 16/10 I/O RELAY OUTPUT , modular smart relay Zelio Logic - 26 I O - 24 V DC - clock - display

Telemecanique logo

Mfr. Number: SR3B261BD

Middy's Part #: TELSR3B261BD

Product Overview

Description

Modular smart relay Zelio Logic, 26 I O, 24 V DC, clock, display. range of product: Zelio Logic - product or component type: modular smart relay. Benefits: .. Applications: .. Benefits: Step into an intuitive world!. Simple to select, install and programme, Zelio Logic is suitable for all your applications. Flexible, it offers you the choice of 2 ranges, Compact, monobloc or Modular, extendable, and 2 programming languages (FBD or LADDER). Open, it also enables the control and monitoring of your installations in any situation, either on site or remotely.... Applications: - BuildIndustry: control systems for small machines, decentralized control systems on equipment annexed to large and medium-sized machines, Building/Service sector: lighting management, access control, control and monitoring, heating and air conditioning control..

Datasheets

Features / Specifications

  • product or component type: modular smart relay
  • range of product: Zelio Logic
  • analogue input number: 6
  • backup time: 10 years at 25 ?C
  • clock drift: 6 s/month at 25 ?C
  • contacts type and composition: NO for relay output
  • conversion error: +/- 5 % at 25 ?C for analogue input circuit
  • conversion error: +/- 6.2 % at 55 ?C for analogue input circuit
  • conversion time: smart relay cycle time for analogue input circuit
  • counting frequency: 1 kHz for discrete input
  • discrete input number: 16 conforming to EN/IEC 61131-2 type 1
  • discrete input voltage: 24 V DC
  • input compatibility: 3-wire proximity sensors PNP (discrete input)
  • input impedance: 12 kOhm (IB...IG used as analogue input circuit)
  • input impedance: 12 kOhm (IB...IG used as discrete input circuit)
  • LSB value: 39 mV (analogue input circuit)
  • maximum permissible voltage: 30 V (analogue input circuit)
  • mechanical durability: 10000000 cycles (relay output)
  • number or control scheme lines: <= 200 with FBD programming
  • number or control scheme lines: 120 with ladder programming
  • number of outputs: 10 relay output(s)
  • operating distance: 10 m between stations with screened cable (sensor not isolated) for analogue input circuit
  • output thermal current: 5 A for 2 outputs (relay output)
  • output thermal current: 8 A for 8 outputs (relay output)
  • output voltage limits: 24...250 V AC (relay output)
  • output voltage limits: 5...30 V DC (relay output)
  • overvoltage category: III conforming to EN/IEC 60664-1
  • power dissipation in W: 10 W with extensions
  • power dissipation in W: 6 W without extension
  • [Uimp] rated impulse withstand voltage: 4 kV conforming to EN/IEC 60947-1 and EN/IEC 60664-1
  • repeat accuracy: +/- 2 % at 55 ?C for analogue input circuit
  • supply current: 190 mA (without extension)
  • supply current: 300 mA (with extensions)
  • [Us] rated supply voltage: 24 V
  • switching capacity in mA: >= 10 mA at 12 V (relay output)
  • voltage state 0 guaranteed: <= 5 V for I1...IA and IH...IR discrete input circuit
  • voltage state 0 guaranteed: <= 5 V for IB...IG used as discrete input circuit
  • voltage state1 guaranteed: >= 15 V for I1...IA and IH...IR discrete input circuit
  • voltage state1 guaranteed: >= 15 V for IB...IG used as discrete input circuit
  • analogue input range: 0...10 V
  • analogue input range: 0...24 V
  • analogue input resolution: 8 bits
  • analogue input type: common mode
  • checks: program memory on each power up
  • clock: with
  • cycle time: 6...90 ms
  • discrete input current: 4 mA
  • discrete input type: resistive
  • local display: with
  • product weight: 0.4 kg
  • reverse polarity protection: with
  • supply voltage limits: 19.2...30 V
  • tightening torque: 0.5 N.m
  • response time: 10 ms (from state 0 to state 1) for relay output
  • response time: 5 ms (from state 1 to state 0) for relay output
  • input impedance: 7.4 kOhm (I1...IA and IH...IR discrete input circuit)
  • current state 0 guaranteed: < 0.5 mA for IB...IG used as discrete input circuit
  • current state 0 guaranteed: < 0.75 mA for I1...IA and IH...IR discrete input circuit
  • current state 1 guaranteed: >= 1.2 mA for IB...IG used as discrete input circuit
  • current state 1 guaranteed: >= 2.2 mA for I1...IA and IH...IR discrete input circuit
  • operating rate in Hz: 0.1 Hz (at Ie) for relay output
  • operating rate in Hz: 10 Hz (no load) for relay output
  • electrical durability: 500000 cycles AC-12 at 230 V 1.5 A for relay output conforming to EN/IEC 60947-5-1
  • electrical durability: 500000 cycles AC-15 at 230 V 0.9 A for relay output conforming to EN/IEC 60947-5-1
  • electrical durability: 500000 cycles DC-12 at 24 V 1.5 A for relay output conforming to EN/IEC 60947-5-1
  • electrical durability: 500000 cycles DC-13 at 24 V 0.6 A for relay output conforming to EN/IEC 60947-5-1
  • clock drift: 12 min/year at 0...55 ?C
  • connections - terminals: screw terminals clamping capacity: 1 x 0.2...1 x 2.5 mm? AWG 25...AWG 14 semi-solid
  • connections - terminals: screw terminals clamping capacity: 1 x 0.2...1 x 2.5 mm? AWG 25...AWG 14 solid
  • connections - terminals: screw terminals clamping capacity: 1 x 0.25...1 x 2.5 mm? AWG 24...AWG 14 flexible with cable end
  • connections - terminals: screw terminals clamping capacity: 2 x 0.2...2 x 1.5 mm? AWG 24...AWG 16 solid
  • connections - terminals: screw terminals clamping capacity: 2 x 0.25...2 x 0.75 mm? AWG 24...AWG 18 flexible with cable end
  • disturbance radiated/conducted: class B conforming to EN 55022-11 group 1
  • environmental characteristic: EMC directive conforming to EN/IEC 61000-6-2
  • environmental characteristic: EMC directive conforming to EN/IEC 61000-6-3
  • environmental characteristic: EMC directive conforming to EN/IEC 61000-6-4
  • environmental characteristic: EMC directive conforming to EN/IEC 61131-2 zone B
  • environmental characteristic: low voltage directive conforming to EN/IEC 61131-2
  • immunity to microbreaks: <= 1 ms
  • pollution degree: 2 conforming to EN/IEC 61131-2
  • altitude transport: <= 3048 m
  • product certifications: CSA
  • product certifications: C-Tick
  • product certifications: GL
  • product certifications: GOST
  • product certifications: UL
  • operating altitude: 2000 m
  • standards: EN/IEC 60068-2-27 Ea
  • standards: EN/IEC 60068-2-6 Fc
  • standards: EN/IEC 61000-4-11
  • standards: EN/IEC 61000-4-12
  • standards: EN/IEC 61000-4-2 level 3
  • standards: EN/IEC 61000-4-3
  • standards: EN/IEC 61000-4-4 level 3
  • standards: EN/IEC 61000-4-5
  • standards: EN/IEC 61000-4-6 level 3
  • ambient air temperature for storage: -40...70 ?C
  • relative humidity: 95 % without condensation or dripping water
  • IP degree of protection: IP20 (terminal block) conforming to IEC 60529
  • IP degree of protection: IP40 (front panel) conforming to IEC 60529
  • ambient air temperature for operation: -20...40 ?C in non-ventilated enclosure conforming to IEC 60068-2-1 and IEC 60068-2-2
  • ambient air temperature for operation: -20...55 ?C conforming to IEC 60068-2-1 and IEC 60068-2-2
  • Warranty period: 12 months
  • Warranty period: 18 months
  • Warranty period: The warranty period is 18 months from the date of delivery which is confirmed by the appropriate document
  • Warranty period: The warranty on the equipment is 18 months from the date of entry into service as evidenced by a relevant document but not more than 24 months from the date of delivery
Show More